Wednesday, October 8, 2014

NetApp Sysstat CP Type

The CP type will give you important information about the health of the ability of the system to write.
Basically, you want to avoid Bs and bs.  B means bad.  B means back to back CP, which means the disks can't keep up with the write workload.
B = Bad
b = even more bad

If you have a B or a b, you need more disks in the aggregate to be able to keep up with the writes.
CP Ty : Consistency Point (CP) type is the reason that a CP started in that interval. The CP types are as follows:
  • - No CP started during sampling interval (no writes happened to disk at this point of time)
  • number Number of CPs started during sampling interval
  • B Back to back CPs (CP generated CP) (The filer is having a tough time keeping up with writes)
  • b Deferred back to back CPs (CP generated CP) (the back to back condition is getting worse)
  • F CP caused by full NVLog (one half of the nvram log was full, and so was flushed)
  • H CP caused by high water mark (rare to see this. The filer was at half way full on one side of the nvram logs, so decides to write on disk).
  • L CP caused by low water mark
  • S CP caused by snapshot operation
  • T CP caused by timer (every 10 seconds filer data is flushed to disk)
  • U CP caused by flush
  • : continuation of CP from previous interval (means, A cp is still going on, during 1 second intervals)
The type character is followed by a second character which indicates the phase of the CP at the end of the sampling interval. If the CP completed during the sampling interval, this second character will be blank. The phases are as follows:
  • 0 Initializing
  • n Processing normal files
  • s Processing special files
  • f Flushing modified data to disk
  • v Flushing modified superblock to disk
CP util : The Consistency Point (CP) utilization, the % of time spent in a CP.  100% time in CP is a good thing. It means, the amount of time, used out of the cpu, that was dedicated to writing data, 100% of it was used. 75% means, that only 75% of the time allocated to writing data was utilized, which means we wasted 25% of that time. A good CP percentage has to be at or near 100%.

NetApp Create a junction path on a CDOT vserver / SVM

Create a junction path manually on a NetApp Cluster-Mode/C-Mode/CDOT System

If you use the GUI to set up the SVM, it does not prompt you to create a data volume the same way as the CLI.  Therefore, the "/vol" directory is missing and you are unable to mount volumes on a junction path /vol.

This is as simple as creating a directory, unfortunately it's not not easy.

The only way I've found to do this is to re-run the vserver setup wizard on the command line, use the same vserver name (don't worry it won't affect the running vceter) and then accept all the defaults, and create a data volume as /vol/volname.

Once it has created the volume, CTRL-C out of the wizard, delete the temporary volume, and mount your volumes on the "/vol/" junction path!

cluster::> vserver setup
Welcome to the Vserver Setup Wizard, which will lead you through 
the steps to create a virtual storage server that serves data to clients.

You can enter the following commands at any time:
"help" or "?" if you want to have a question clarified,
"back" if you want to change your answers to previous questions, and 
"exit" if you want to quit the Vserver Setup Wizard. Any changes 
you made before typing "exit" will be applied.

You can restart the Vserver Setup Wizard by typing "vserver setup". To accept a default 
or omit a question, do not enter a value.

Vserver Setup wizard creates and configures only data Vservers.
If you want to create a Vserver with Infinite Volume use the vserver create command.


Step 1. Create a Vserver.
You can type "back", "exit", or "help" at any question.

Enter the Vserver name: [CURRENT-VSERVER-NAME]
Choose the Vserver data protocols to be configured {nfs, cifs, fcp, iscsi, ndmp} [nfs,cifs,fcp,iscsi]: [HIT ENTER]
Choose the Vserver client services to be configured {ldap, nis, dns}: [HIT ENTER]
Vserver SVMNAME's allowed protocol list has been modified to nfs,cifs,fcp,iscsi


Step 2: Create a data volume 
You can type "back", "exit", or "help" at any question.

Do you want to create a data volume? {yes, no} [yes]: [HIT ENTER]
Enter the volume name [vol9]: [HIT ENTER]
Enter the name of the aggregate to contain this volume {AGGR1, AGG2} [AGGR2]: [HIT ENTER]
Enter the volume size: [SOME SMALL SIZE LIKE 2G]
Enter the volume junction path [/vol/vol9]: [HIT ENTER]
It can take up to a minute to create a volume...


Volume vol9 of size 2GB created on aggregate AGGR2 successfully.
Do you want to create an additional data volume? {yes, no} [no]:[HIT CTRL-C] 

Exiting the vserver setup wizard. Any changes you have made so far have been saved.

Warning: You have exited the vserver setup wizard before completing all
of the tasks. The vserver is not configured completely. You can complete setup
by typing "vserver setup" in the command line interface.

cluster::> vol mount -volume VOLNAME -junction-path /vol/volname
  (volume mount)

Tuesday, October 7, 2014

NetApp DataFabric / OnCommand Unified Manager 5.x - DFM Sybase ASA Database service won't start

NetApp DataFabric / OnCommand Unified Manager 5.x - DFM Sybase ASA Database service won't start

Symptoms:

You won't be able to log into DFM...but the web server is running.  When attempting to log in you get the following error:

Could not connect to host "SERVERNAME" on port 8488.

=== CLIENT ===
Version=3.3.0.8036
Build=3.3P2
OS Name=Windows Server 2008 R2
OS Arch=x86
OS Version=6.1

=== ERROR ===
com.netapp.nmf.main.ConnectionRefusedException

=== MESSAGE ===
Could not connect to host "SERVERNAME" on port 8488.

=== DETAILS ===
The server refused a connection on the indicated port.  This means that there is no network service listening on that port.

The default server ports for DataFabric Manager server are 8088 for HTTP and 8488 for HTTPS.

=== CORRECTIVE ACTION ===
Check that the port number you entered is correct.  If it is correct, make sure the service is started on the server for the port you specified.

=== STACK TRACE ===
com.netapp.nmf.main.ConnectionRefusedException: Could not connect to host "accs001mgt01.accs.int" on port 8488.
at com.netapp.nmf.main.ConnectionException.createException(ConnectionException.java:60)
at com.netapp.nmf.main.DialogApiManager.displayErrorDialog(DialogApiManager.java:720)
at com.netapp.nmf.main.DialogApiManager.showLoginDialog(DialogApiManager.java:221)
at com.netapp.nmf.main.SumoMainFrame.doInitialLogin(SumoMainFrame.java:179)
at com.netapp.nmf.main.SumoMainFrame.<init>(SumoMainFrame.java:149)
at com.netapp.nmf.main.SumoMainComponent.initFrame(SumoMainComponent.java:21)
at com.netapp.nmf.main.MainPlugin.initFrame(MainPlugin.java:637)
at com.netapp.nmf.main.MainPlugin.createAndShowGUI(MainPlugin.java:237)
at com.netapp.nmf.main.MainPlugin$2.run(MainPlugin.java:715)
at java.awt.event.InvocationEvent.dispatch(Unknown Source)
at java.awt.EventQueue.dispatchEventImpl(Unknown Source)
at java.awt.EventQueue.access$000(Unknown Source)
at java.awt.EventQueue$1.run(Unknown Source)
at java.awt.EventQueue$1.run(Unknown Source)
at java.security.AccessController.doPrivileged(Native Method)
at java.security.AccessControlContext$1.doIntersectionPrivilege(Unknown Source)
at java.awt.EventQueue.dispatchEvent(Unknown Source)
at java.awt.EventDispatchThread.pumpOneEventForFilters(Unknown Source)
at java.awt.EventDispatchThread.pumpEventsForFilter(Unknown Source)
at java.awt.EventDispatchThread.pumpEventsForHierarchy(Unknown Source)
at java.awt.EventDispatchThread.pumpEvents(Unknown Source)
at java.awt.EventDispatchThread.pumpEvents(Unknown Source)
at java.awt.EventDispatchThread.run(Unknown Source)
Caused by: netapp.sumo.toolkit.zephyr.NaIOException: java.net.ConnectException: Connection refused: connect
at netapp.sumo.toolkit.zephyr.ZephyrServer.invoke(ZephyrServer.java:277)
at netapp.sumo.toolkit.zephyr.SimpleApiManager.getResult(SimpleApiManager.java:25)
at netapp.sumo.toolkit.zephyr.LoggingApiManager.getResult(LoggingApiManager.java:116)
at netapp.sumo.toolkit.zephyr.SharedCredentialApiManager.getResult(SharedCredentialApiManager.java:79)
at com.netapp.nmf.main.DialogApiManager.access$401(DialogApiManager.java:48)
at com.netapp.nmf.main.DialogApiManager$RequestContext.callApiSuper(DialogApiManager.java:881)
at com.netapp.nmf.main.DialogApiManager.getServerInfo(DialogApiManager.java:469)
at com.netapp.nmf.main.DialogApiManager.access$000(DialogApiManager.java:48)
at com.netapp.nmf.main.DialogApiManager$1.sendRequest(DialogApiManager.java:434)
at com.netapp.nmf.main.DialogApiManager$1.sendRequest(DialogApiManager.java:431)
at com.netapp.nmf.userinterface.util.task.ServerTask$1.run(ServerTask.java:47)
at foxtrot.AbstractWorkerThread$1.run(AbstractWorkerThread.java:39)
at java.security.AccessController.doPrivileged(Native Method)
at foxtrot.AbstractWorkerThread.runTask(AbstractWorkerThread.java:35)
at foxtrot.workers.SingleWorkerThread.run(SingleWorkerThread.java:196)
at foxtrot.workers.SingleWorkerThread.run(SingleWorkerThread.java:179)
at java.lang.Thread.run(Unknown Source)
Caused by: java.net.ConnectException: Connection refused: connect
at java.net.PlainSocketImpl.socketConnect(Native Method)
at java.net.PlainSocketImpl.doConnect(Unknown Source)
at java.net.PlainSocketImpl.connectToAddress(Unknown Source)
at java.net.PlainSocketImpl.connect(Unknown Source)
at java.net.SocksSocketImpl.connect(Unknown Source)
at java.net.Socket.connect(Unknown Source)
at com.sun.net.ssl.internal.ssl.SSLSocketImpl.connect(Unknown Source)
at com.sun.net.ssl.internal.ssl.SSLSocketImpl.<init>(Unknown Source)
at com.sun.net.ssl.internal.ssl.SSLSocketFactoryImpl.createSocket(Unknown Source)
at netapp.manage.http.HTTPClient.<init>(HTTPClient.java:556)
at netapp.manage.NaServer.getSession(NaServer.java:335)
at netapp.manage.NaServer.invokeHTTP(NaServer.java:868)
at netapp.manage.NaServer.invokeElemForXML(NaServer.java:716)
at netapp.manage.NaServer.invokeElem(NaServer.java:635)
at netapp.sumo.toolkit.zephyr.ZephyrServer.invoke(ZephyrServer.java:265)
... 16 more

You also will have these Event IDs on the DFM server:

EventID:   1
Source:     SQLANY64 16.0

The description for Event ID 1 from source SQLANY64 16.0 cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer.

If the event originated on another computer, the display information had to be saved with the event.

The following information was included with the event: 

DFMSybase
Could not start server

Event ID:  124
Source:      OnCommandHostSvc

Communication failure between HostAgent and DFM server: Could not connect to https://servername:8488/apis/soap/v1. TCP error code 10061: No connection could be made because the target machine actively refused it IPADDRESS:8488.   Please make sure DFM server is up running.

Cause

After discovering that it was the database service that wouldn't start (since the Event IDs are useless) I found the database log here:

C:\Program Files\NetApp\DataFabric Manager\DFM\log\sybase.log

After scrolling around a bit, I found the following error:


I. 10/07 14:46:42. Starting database "monitordb" (C:\Program Files\NetApp\DataFabric Manager\DFM\data\monitordb.db) at Tue Oct 07 2014 14:46
I. 10/07 14:46:42. Performance warning: Database file "C:\Program Files\NetApp\DataFabric Manager\DFM\data\monitordb.db" consists of 70 disk fragments
I. 10/07 14:46:43. Transaction log: monitordb.log
E. 10/07 14:46:43. Error: Database cannot be started -- monitordb.log is an invalid transaction log

E. 10/07 14:46:43. Database cannot be started -- monitordb.log is an invalid transaction log
I. 10/07 14:46:43. Database server shutdown due to startup error
I. 10/07 14:46:43. Database server stopped at Tue Oct 07 2014 14:46


Resolution

The bad transaction log file was located here:

C:\Program Files\NetApp\DataFabric Manager\DFM\data\monitordb.log

I renamed monitordb.log to monitordb.old

And then I attempted to start the Sybase database service again - and it worked!

net start DFMSybase

So I started the rest of the DFM services:

net start DFMServer
net start DFMWatchDog
net start DFMWebUI
net start DFMScheduler
net start DFMMonitor
net start DFMApache
net start DFMEvent

You may have a lot a little data in the database file, but you've lost more with teh services being stopped, so don't fret.  Delete the bad transaction log file and move on.


NetApp: LUN Migration - 7-Mode to C-Mode/C-DOT

CDOT/C-Mode LUN/block FC/FCoE/iSCSI storage migration

NetApp made a huge improvement in their software moving to C-Mode, however they did not make the process to move block storage LUNs easy.  Of course, they would like you to buy their DTA2800 appliance, which is licensed per TB migrated, and/or use their professional services.

Like most of us, we more than a couple TB to move, and I don't feel I should have to pay for the migration since I bought both systems in the first place.  The good news is you don't have to....if you can deal with a little downtime.

The solution is to use the NetApp Workflow Automation tool or "WFA".  You can do offline and online block LUN replication, and with the online mode - the cutover period can be very short.

Unfortunately, the pieces needed to easily complete this task are not readily compiled and comprehensively documented.

So far, the best document is NetApp TR 4314 which is not publicly accessible - except from this scribd post.  I will not post the actual PDF - but if you have access to the NetApp field portal - you can get EVERYTHING you need to complete the migrations.

Resources:

Instructions:
  1. Install OnCommand Workflow Automater
  2. Acquire all the items listed above
  3. Follow the instructions in TR 4314 to set up WFA
  4. Build a test LUN on your 7-Mode System
  5. Wait a minute for OCUM to update, and...
Recommendations/Notes:
  • Make sure the administrative interfaces, intercluster interfaces, and replication IPs are all on 10-gigabit networks so the network is not your bottleneck in the migration process.
  • If you have a spare NetApp, use this system as a staging system between the source and destination systems.  I happened to have a spare system with a couple hundred 15k drives and multiple 10GbE interfaces which worked great as an intermediary.
  • There are a bunch of workflows, but don't be overwhelmed.  You really only need one for the initial setup, and three for most migrations.
Steps to Migrate:

Set up the igroups.  You should only need to run this once per source controller/HA pair if your igroups were set up correctly to begin with.
  1. Run the "7toC LUN Migrate igroups" workflow
  2. Select the source array
  3. Select the target cluster
  4. Select the target SVM
  5. Click Execute
  6. Wait for the workflow to execute, make sure it completes successfully
  7. Check the CDOT system
Pre-Migration - "Baseline"
  1. Run the "7toC LUN Migrate Job Baseline" workflow
  2. Select the source system (your 7-Mode controller)
  3. Select the volume, when selecting you can see how many LUNs are on that volume.
  4. Select the replication IP - this IP needs to be on the same VLAN or routeable to the staging and target systems.  Hopefully it's a 10GbE interface as well.
  5. If there is more than one LUN per volume, you can use a regex to describe the LUN(s) you wish to migrate.  If you want to do one LUN at a time (I recommend this) just put the LUN name in the "LUN Pattern" field.
  6. Select the staging system, replication IP, vfiler and NFS access IP.
  7. Select the target cluster, SVM, aggregate
  8. Enter the volume name...I like to name my block volumes LUNNAME_vol but your mileage may vary
  9. Click Execute
  10. Wait a while - if you can, keep the workflow execution status window up so you can familiarize yourself with the process
  11. Hopefully it completes successfully.  If not look at what step of the workflow failed and troubleshoot it
Migration - "Cutover"

IMPORTANT: Leave all the checkboxes at default unless you are going to read the documentation and see what they all do.
  1. Run the "7toC LUN Migrate Job Update + Cutover - Rapid" workflow
  2. Leave the offline source LUNs box checked
  3. Select the target cluster
  4. Select the target SVM
  5. Select the volume - in the dropbox, it will show you the status of the volume - it should be in the state"baselined"
  6. Leave the remap LUNs box checked
  7. Shut down the source system (if this is a boot LUN) or stop all applications using the LUN(s)
  8. Unmount the disks in the source OS
  9. Click the "Execute" button
  10. The workflow will typically take about five minutes to execute on a fast system - unless there is a substantial amount of change since the initial baseline.
  11. If the LUN migrated was a boot LUN, make sure to update the boot targets in the BIOS (or boot policy in UCS)
  12. If the LUN migrated was a data/application LUN, mount the LUN in the OS and test the application
Post-Migration - "Cleanup"

IMPORTANT: Leave all the checkboxes at default unless you are going to read the documentation and see what they all do.
  1. Run the "7toC LUN Migrate Job Cleanup" workflow
  2. Select the target cluster
  3. Select the target SVM
  4. Select the target volume - the state should be "cutover"
  5. Click Execute
Manual Post-Migration Steps

The original 7-mode LUN should be offline, and the LUN and volume will be intact.  Once you are satisfied with the migration, you may remove the source data.
  1. Delete the source LUN
  2. Offline the source LUN volume/container (make sure it's the only LUN in the volume)
  3. Delete the source LUN container

Monday, October 6, 2014

How to upgrade VMware tools on Linux

If you are looking for how to INSTALL VMware Tools, please see my other blog post: How to install VMware Tools on Linux


How to upgrade VMware tools on Linux: Steps

1. Open the console of your Linux virtual machine

2. Log in as root

3. Go to the VM Menu, Guest, Install/Upgrade VMware Tools

4. Make a cdrom mount directory (if there isn't one already)

mkdir /mnt/cdrom

5. Mount the cdrom/iso

mount /dev/cdrom /mnt/cdrom

6.  Change directory to the mounted cdrom path

cd /mnt/cdrom

7. List the directory contents, you are looking for VMwareTools-version#-build#.tar.gz.  Take note of the build number.

ls

7. Clear out the old files from the root directory, if you used my previous instructions you will need to do this:

rm -rf ~/vmware-tools-distrib
rm -rf ~/VMwareTools*.tar.gz

8. Copy the new VMware Tools file to the root home directory

cp VMwareTools*.tar.gz ~

9. Change directory to the root home directory

cd

10. Expand the VMware Tools archive

tar -zxf VMwareTools*.tar.gz

11. List the contents of the root directory, look for the vmware-tools-distrib directory- change to that directory

cd vmware-tools-distrib

12. List the contents of that directory, look for the vmware install perl script and run it

./vmware-install.pl

13. Follow the installation/upgrade script - usually the defaults work fine.

14. Once the installation finishes, it will ask you if you want to run the configuration script, say yes.  Again, the defaults usually work for most everyone, most of the time.

14. Once the install has finished, unmount the ISO

umount /dev/cdrom

15. Go to the VM menu, Guest, if "End Vmware Tools Install" is an option, select that.  Otherwise, you are done!

Reconfigure VMware Tools

As a side note, if you every want to reconfigure VMware tools (for example, if you upgrade your Linux OS to a new kernel rev) you can always do the following:

1. Log in as root

2. Run the config script manually

vmware-config-tools.pl


How to install VMware tools on Linux

It has come to my attention that many people don't know how to install VMware tools on Linux, so they don't bother.  Linux isn't hard people!  I've decided to make it easy for you, so you no longer have any excuses.

If you are looking for how to UPGRADE VMware Tools, please see my other blog post: How to upgrade VMware Tools on Linux

How to install VMware tools on Linux: Steps

1. Open the console of your Linux virtual machine

2. Log in as root

3. Go to the VM Menu, Guest, Install VMware Tools

4. Make a cdrom mount directory (if there isn't one already)

mkdir /mnt/cdrom

5. Mount the cdrom/iso

mount /dev/cdrom /mnt/cdrom

6.  Change directory to the mounted cdrom path

cd /mnt/cdrom

7. List the directory contents, you are looking for VMwareTools-version#-build#.tar.gz

ls

7. Copy the VMware Tools file to the root home directory

cp VMwareTools*.tar.gz ~

8. Change directory to the root home directory

cd

9. Expand the VMware Tools archive

tar -zxf VMwareTools*.tar.gz

10. List the contents of the root directory, look for the vmware-tools-distrib directory- change to that directory

cd vmware-tools-distrib

11. List the contents of that directory, look for the vmware install perl script and run it

./vmware-install.pl

12. Follow the installation script - usually the defaults work fine.  If you get errors, you may need to install perl or gcc to be able to correctly install VMware tools.  Follow the correct instructions for your OS to install this.

13. Once the installation finishes, it will ask you if you want to run the configuration script, say yes.  Again, the defaults usually work for most everyone, most of the time.

14. Once the install has finished, unmount the ISO

umount /dev/cdrom

15. Go to the VM menu, Guest, if "End Vmware Tools Install" is an option, select that.  Otherwise, you are done!

Reconfigure VMware Tools

As a side note, if you every want to reconfigure VMware tools (for example, if you upgrade your Linux OS to a new kernel rev) you can always do the following:

1. Log in as root

2. Run the config script manually

vmware-config-tools.pl



Sunday, October 5, 2014

pbm.fault.PBMFault.summary on vMotion

After upgrading to ESX 5.5 U2 and vCenter 5.5 U2 - I was receiving the following error during a system-initated or manual vMotionrequest:

pbm.fault.PBMFault.summary



After restarting the "VMware vSphere Profile-Driven Storage Service" on the vCenter server, I was able to successfully vMotion.

c:\> net stop vimPBSM
c:\> net start vimPBSM